- The video explains how to perform the concrete slump (revenimiento) test, also known as the slump test.
- Purpose: determine concrete workability—how easy it is to place, handle, and compact the concrete.
- The key output is the slump value, measured as the difference in height after the cone is lifted.
Methodology / step-by-step procedure (detailed)
Equipment needed
- Standard slump cone (Abrams cone)
- Small scoop (to take/fill the concrete sample)
- Smooth, round-tipped compaction rod
- Measuring tape
- Metal plate (to place the cone on)
Preparation
- Take a concrete sample and homogenize the mix (ensure it’s uniform).
- Clean and moisten the slump cone beforehand.
- Place the cone on a clean, firm, level, non-absorbent metal plate.
Filling and compaction (in 3 layers)
- Stand firmly on the cone’s stirrups (located on the sides).
- Fill the cone with concrete to 1/3 of its volume.
- Compact the first layer with the rod using 25 strokes.
- Fill the cone to 2/3 of its volume (second layer).
- Compact this layer with 25 strokes.
- Use the same principle as shown: lightly compact the previous layer so the rod interacts appropriately at the layer boundary.
- Fill the cone to the top with the third layer (it should overflow slightly).
- Compact with 25 strokes.
- The rod should go up to the top of the second layer, not all the way down to the first layer.
Finishing
- Level the surface using a steel rod with a rolling motion.
Cone lifting
- Clean concrete around the base and top of the cone.
- Lift the cone carefully and vertically.
- Ensure the concrete mixture does not move laterally during lifting.
Measurement (slump value)
- Measure the vertical drop (slump) as the difference between:
- the center reference point of the mixture top, and
- the top after lifting.
- The subtitles indicate an example result: “Lower part of rod 14… we already get the slump 15.”
Acceptance / failure criteria and actions
- If the slump is out of tolerance (too high or too low):
- Take another sample.
- If the second sample also fails:
- Reject the remaining mixture.
Speakers / sources featured
- Eling David (speaker/host, presenting the test)